Fireproof Material Testing
Fireproof board, fireproof coating, fireproof sealing material, fireproof insulation material, fireproof door, fireproof rolling shutter, fireproof glass, fireproof sealing element, cable fireproof coating, fireproof sealing system, fireproof decorative material, aluminum-plastic composite fireproof board, fireproof composite material, fireproof insulation integrated board.
- Fast Delievery
- Quality Assurance
- 24/7 Customer Service
Product Introduction

Testing Scope
Fireproof board, fireproof coating, fireproof sealing material, fireproof insulation material, fireproof door, fireproof rolling shutter, fireproof glass, fireproof sealing element, cable fireproof coating, fireproof sealing system, fireproof decorative material, aluminum-plastic composite fireproof board, fireproof composite material, fireproof insulation integrated board
detection content
Combustion performance classification: A1/A2 (non combustible), B1 (flame retardant), B2 (combustible), B3 (flammable)
Non combustibility: furnace temperature rise ≤ 50 ℃, mass loss rate ≤ 50%, continuous combustion time ≤ 20s
Flammability: combustion length, self extinguishing time, droplet ignitability
Extreme Oxygen Index: The minimum oxygen concentration required to maintain combustion (A1 level ≥ 90%, B1 level ≥ 32%)
Heat release rate: peak heat release rate (PHRR), total heat release (THR)
Smoke Density: Maximum Optical Density (Dm), Smoke Density Rating (SDR)
Combustion calorific value: Total calorific value (PCS), Net calorific value (PCI)
Smoke toxicity: concentration of toxic gases such as CO and HCN, toxicity index ≤ 1.0
Fire resistance limit: the time required to maintain integrity and insulation under the standard heating curve (divided by component type into 30/60/90/120 minutes, etc.)
Bonding strength: Bonding strength with substrate (steel structure fireproof coating ≥ 0.15MPa)
Coating thickness: Thin/ultra-thin qualified point rate ≥ 80%, thinnest part ≥ 90% of design thickness
Weather resistance: resistance to cold and hot cycles, salt spray, water resistance, moisture and heat resistance
Construction performance: drying time (surface drying ≤ 4h, actual drying ≤ 24h), flowability, adhesion
Electric welding spark test: resistance to welding spark of foam insulation material
Thermal conductivity: Thermal conductivity of insulation and fireproof materials
Impact resistance: the ability to maintain fire resistance after withstanding external impact
Durability: retention rate of fire resistance after long-term use

Testing standard
GB/T 8624-2025 Classification of Combustion Performance of Building Materials and Products
GB/T 8624-2012 Classification of Burning Behavior of Building Materials and Products
GB/T 5464-2010 Test Method for Non combustibility of Building Materials
GB/T 8626-2017 Test Method for Flammability of Building Materials
GB/T 10707-2022 Determination of rubber combustion performance
GB/T 14402-2007 Test Method for Combustion Heat Value of Building Materials
GB/T 16172-2007 Test Method for Thermal Release Rate of Building Materials
GB/T 20284-2006 Single Unit Combustion Test for Building Materials or Products
GB/T 20285-2006 Classification of Toxicity Hazards for Smoke Production of Materials
GB 14907-2018 General Technical Conditions for Fire resistant Coatings for Steel Structures
GB 28375-2025 Fire resistant Coatings for Concrete Structures
GB/T 15442.1-2019 Decorative Fireproof Coatings Part 1: Technical Requirements
GB/T 15442.2-2019 Decorative fireproof coatings Part 2: Test methods
GB/T 22282-2008 Test method for flame retardancy of building materials
GB 23864-2023 Fireproof Sealing Materials
GB/T 34411-2017 Test Method for Fire Resistance Performance of Building Fire Sealing Systems
GB/T 25970-2010 Rock wool products for external insulation of building exterior walls
GB/T 30595-2014 Test Method for Fire Performance of Exterior Insulation Systems for Building Walls
GB/T 29416-2012 Fireproof Glass for Buildings Part 1: Single piece Fireproof Glass
GB/T 9978.1-2008 Fire resistance test methods for building components Part 1: General requirements
GB/T 9978.2-2008 Fire resistance test methods for building components Part 2: Determination of fire integrity, insulation and heat flux
GB/T 12513-2021 Fire resistance test method for glazed components
GB/T 27904-2011 Fire resistance test method for fire doors
GB/T 7633-2008 Fire resistance test method for doors and rolling shutters
was established in 2011. As a national high-tech enterprise recognized by the Zhejiang Provincial Higher People's Court as a judicial authentication institution for construction engineering quality, we specialize in structural performance testing and safety assessment of construction projects, special equipment, communication towers, electromagnetic environments, large bridges, and building safety appraisal.
The company has more than 100 professional and technical personnel, over 90% of whom hold various medium and senior technical certificates. Equipped with complete testing equipment worth over RMB 10 million, our business scope covers the whole country.





No Information











